Dataset

mlearn_Ge_test



Download Dataset XYZ file

Name mlearn_Ge_test
Extended ID mlearn_Ge_test_ZuoChenLiDengChenBehlerCsanyiShapeevThompsonWoodOng__DS_wmj0lbhn2nob_0
Description A comprehensive DFT data set was generated for six elements - Li, Mo, Ni, Cu, Si, and Ge. These elements were chosen to span a variety of chemistries (main group metal, transition metal, and semiconductor), crystal structures (bcc, fcc, and diamond) and bonding types (metallic and covalent). This dataset comprises only the Ge configurations
Authors Yunxing Zuo
Chi Chen
Xiangguo Li
Zhi Deng
Yiming Chen
Jörg Behler
Gábor Csányi
Alexander V. Shapeev
Aidan P. Thompson
Mitchell A. Wood
Shyue Ping Ong
Elements Ge (100.0%)
Number of Data Objects 25
Number of Configurations 25
Number of Atoms 1,568
Links https://doi.org/10.1021/acs.jpca.9b08723
https://github.com/materialsvirtuallab/mlearn
Configuration Sets by Name Ge_vacancy — NVT AIMD simulations of the bulk supercells with a single vacancy performed at 300 K and 2.0x of the melting point of each element. The bulk supercells were heated from 0 K to the target temperatures and equilibrated for 20,000 time steps. A total of 40 snapshots were obtained from the subsequent production run of each AIMD simulation at an interval of 0.1 ps.
Ge_AIMD_NVT — NVT ab initio molecular dynamics (AIMD) simulations of the bulk supercells performed at 300 K and 0.5x, 0.9x, 1.5x, and 2.0x of the melting point of each element with a time step of 2 fs. The bulk supercells were heated from 0 K to the target temperatures and equilibrated for 20 000 time steps. A total of 20 snapshots were obtained from the subsequent production run in each AIMD simulation at an interval of 0.1 ps.
Ge_surface — Slab structures up to a maximum Miller index of three, including (100), (110), (111), (210), (211), (310), (311), (320), (321), (322), (331), and (332), as obtained from the Crystalium database.
Ge_strain — Strained structures constructed by applying strains of -10% to 10% at 2% intervals to the bulk supercell in six different modes. The supercells used are the 3 x 3 x 3, 3 x 3 x 3, and 2 x 2 x 2 of the conventional bcc, fcc, and diamond unit cells, respectively
Configuration Sets by ID CS_t5efv4qcqra3_0
CS_8zhd2zk11bdu_0
CS_w71gyte2l9j9_0
CS_i82zq52fa19e_0
Data Objects
ColabFit ID DS_wmj0lbhn2nob_0
Files colabfitspec.json

No uploaded content is transferred in ownership from the original creators to ColabFit. All content is distributed under the license specified by its contributor who has stated that he or she has the authority to share it under the specified license.